skip to content

Vega Sewage and Fat Destroyer

Vega Sewage & Fat Destroyer (SFD) is a range of natural bacteria and enzyme products that digest grease, fat, hair, paper and sewage in septic tanks, grease traps, drains and sewage sumps. The bacteria turn the waste into water, carbon dioxide and mineral ash, which reduces blockages, odours and pump-outs without harsh chemicals. This guide explains which product to use where, how to dose it and current prices.

 

 

Bacteria Count

8 × 108 /g

SFD100 aerobic, natural strains

 

 

Working Range

pH 5 – 8.5, to 50 °C

SFD100 powder

 

 

Starter Pack

R71

400 g, 4 × 100 g sachets

How biological treatment works

Enzymes break large molecules of fat, protein and starch into pieces small enough for bacteria to eat. The bacteria in SFD are dormant in the pack and revive within minutes of meeting water, then multiply and spread through the system. Each product combines enzymes with selected, naturally occurring (not genetically engineered) bacteria.

Chemicals kill the bacteria. Bleach, strong drain cleaners, disinfectants and ammonia stop biological action. Do not use SFD together with ammonia, and keep harsh chemicals out of septic tanks and grease traps you are treating.

Which product for which job?

ProductWhat it isUse it forPack and price
SFD100 Sewage & Fat DestroyerPowder: bacteria and enzymes on a cereal and salt baseSeptic tanks, pit toilets, drains, sumps, lift stations, holding tanks400 g R71
25 kg R4 368
SFD101 Surface CleanerGel with a bacillus consortium producing seven enzymesDrain lines, grease traps, surfaces and odour control5 L R188
25 L R939
SFD102 Multi EnzymeFood-grade floor cleaner concentrate, surfactant plus enzymesKitchens and food areas: greasy floors, grout and embedded grime5 L R282
25 L R1 408
SFD103 Grease Trap LiquidMulti-strain bacteria for fats, oils and greaseGrease traps and drain lines5 L R419
25 L R2 096
SFD104 Grease Trap BlocksSlow-release solid blocks, dosing for about 30 days eachGrease traps and grey-water tanks without a dosing pump10 blocks R500
SFD105 Grease Trap PowderPowder for fats, oils and greaseMeat, poultry and food processing pre-treatment tanks and pondsR2 815
SFD110 LiquidSpore-based multi-strain liquid concentrateGrease traps and drains dosed automatically by a dosing pump5 L R2 190
25 L R10 947

SFD100 dosing guide

A guideline from the manufacturer. Mix the powder with water at room temperature (not hot) and apply when no water will be drained for six to eight hours, so the bacteria can settle into the waste.

ApplicationInitial doseMaintenance dose
Septic tanks, pit toilets, grease traps100 g per week100 g per month
Industrial effluent, e.g. abattoir1% for 3 days (w/w)0.3% per day (w/w)
Agricultural waste4% once off (w/w)1% weekly (w/w)
Trickling filter0.1% once off (w/w)0.05% weekly (w/w)
Anaerobic digester, oxidation pond, activated sludge1% for 3 days (w/w)1% weekly (w/w)

Effluent outside pH 5 – 8.5 should be corrected with a suitable acid or lime before dosing.

SFD100 characteristics

PropertyValue
Aerobic bacteriaNot less than 8 × 108 per gram
Heavy metalsLess than 50 ppm
Aflatoxins, antibiotic activity, E. coliAbsent
AppearanceTan, low-dusting powder on a cereal / salt base
SolubilityMore than 80% in water
pH range5.0 – 8.5
TemperatureUp to 50 °C
Packaging400 g tube of 4 × 100 g sachets; 25 kg bag

Where it helps pumps

Grease and fat build up on float switches, pump impellers and sump walls, causing pumps to stick on or off and blocking rising mains. Regular SFD dosing in a sewage sump or grease trap keeps floats free and reduces the solids a Vega sewage pump has to handle.

Price guide

RangeItemsPrice range
Vega Sewage & Fat Destroyer range12R71 – R10 947Shop

Frequently asked questions

Is Vega SFD safe for septic tanks?

Yes. It is a biological product that digests organic waste and does not attack plumbing, people or the environment. It restores the bacteria that household chemicals kill.

How much SFD100 do I use in a septic tank?

As a guideline, 100 g per week to start, then 100 g per month for maintenance.

Can I use SFD with bleach or drain cleaner?

No. Chemicals kill the bacteria. Do not use it with ammonia, and avoid harsh cleaners in the treated system.

How long does a grease trap block last?

Each SFD104 block releases bacteria continuously for about 30 days, depending on the flow through the trap.

Which product is best for a restaurant grease trap?

SFD103 liquid or SFD104 blocks for regular treatment, or SFD110 liquid with a dosing pump for automatic dosing.

Does SFD help with odours?

Yes. By digesting the organic waste that rots and smells, it reduces odours from drains, traps and septic tanks.

Not sure which product to use?

Tell us the system, septic tank, grease trap, sump or effluent pond, its size and the problem you see. We will recommend the product and dose.