skip to content

Vega Sewage Pumps

A Vega submersible sewage pump sits in the sump, septic tank or pump station and pushes waste water and solids up to the sewer or drainage point. Vega builds four types: stainless steel vortex pumps and screened cast iron pumps for grey water and drainage, static-cutter pumps that shred raw sewage, and heavy channel-impeller pumps for municipal and industrial pump stations. This guide shows which type suits your waste water, the full specifications and current prices.

 

 

Power Range

0.18 – 45 kW

220V, 380V and 525V

 

 

Maximum Flow

Up to 550 m³/h

200B422 channel pump

 

 

Maximum Head

Up to 42 m

50B25.5

 

 

Solids Handling

15 – 70 mm

Or shredded by cutter

 

 

Raw Sewage Pumps

From R7 749

C range cutter, incl. VAT

 

 

Screened Pumps

From R1 853

WSD cast iron, incl. VAT

Which Vega sewage pump for your waste water?

Waste waterVega rangeWhy
Grey water, drainage, rain and flood water with small solidsWSD / WS screened cast ironSuction screen and open-channel impeller, low price
Grey water and light sewage, corrosive or where rust is a problemVX / VXM stainless steel vortexVortex impeller passes solids up to 35 mm without clogging
Raw sewage with toilet waste, long or narrow rising mainC range static cutterCutter shreds solids and stringy material before the impeller
Pump stations, large buildings, municipal and mining effluentB range channel impellerHigh flow, large solids passage, up to 45 kW
Corrosive effluent where stainless steel is requiredWQK stainless steelStainless steel submersible sewage pump, 380V and 525V

Screened pumps are not for raw sewage. The WSD and VX ranges pass small solids only. Toilet waste, wipes and rags block them. Use a C range cutter pump or a B range channel pump for raw sewage, and keep wipes out of the system whatever pump you choose.

VX and VXM stainless steel vortex pumps

Stainless steel body with a recessed vortex impeller that spins the water rather than pushing solids through the blades. Maximum solids 35 mm, 2" outlet, liquid up to 40 °C. The single-phase VXM is fitted with a float level switch for automatic operation.

ModelPowerMax headFlow rangeWeight220V (VXM)415V (VX)
VX(M)10-1A0.55 kW7.3 mUp to 18 m³/h7.6 kgR4 119R4 119
VX(M)12-1A0.75 kW9.5 mUp to 21 m³/h8.4 kgR4 324R4 324

WSD and WS screened cast iron pumps

Cast iron construction with an open-channel impeller behind a suction screen, for drainage, grey water and screened sewage. WSD models are single-phase 220–240V; WS models are three-phase 380–415V. The model code gives the nominal flow in m³/h and the head in metres: the WSD20-15 is about 20 m³/h and 15 m.

ModelPowerMax headOutletParticle size220V (WSD)380V (WS)
WS(D)8-70.18 kW7.1 m1¼"15 mmR1 883R1 853
WS(D)9-80.25 kW8.0 m1¼"15 mmR1 956R1 916
WS(D)20-120.55 kW12.1 m2"20 mmR2 655R2 655
WS(D)20-150.75 kW15.5 m2"20 mmR2 971R2 971
WS(D)25-151.1 kW15.1 m2"25 mmR3 414R3 414
WS(D)28-181.5 kW18.2 m2"25 mmR3 785R3 785
WS(D)35-222.2 kW22.0 m2"25 mmR5 405R4 980
WS(D)60-203 kWAbout 20 m–––R5 734
WS(D)65-253.7 kWAbout 25 m–––R6 080

C range raw sewage pumps with static cutter

The star-shaped inlet plate grabs stringy solids and the cutter chops them to manageable sizes before they reach the impeller. That lets the C range pump raw sewage through a smaller rising main without blocking. Cast iron, maximum immersion depth 10 m, liquid up to 40 °C.

ModelPowerSupplyOutletMax flowMax headPrice
50C21.1S1.1 kW220VDN5027 m³/h15 mR7 964
50C21.11.1 kW380VDN5027 m³/h15 mR7 749
50C21.51.5 kW380VDN5031 m³/h13 mR8 997
50C22.22.2 kW380VDN5035 m³/h17 mR9 829
80C23.03.0 kW380VDN8067 m³/h21 mR12 914
80C24.04.0 kW380VDN8079 m³/h24 mR14 205
100C25.55.5 kW380VDN100107 m³/h27 mR18 294
100C27.57.5 kW380VDN100135 m³/h30 mR24 379

B range channel-impeller pumps

Heavy cast iron pumps for pump stations and large flows, with a channel impeller and large solids passage. Maximum immersion depth 20 m, liquid up to 40 °C, 380–415V.

ModelPowerOutletMax flowMax headSolidsPrice
50B25.55.5 kWDN5052 m³/h42 m20 mmR13 669
150B41111 kWDN150260 m³/h24 m65 mmR41 586
200B41515 kWDN200490 m³/h21 m70 mmR48 437
200B41918.5 kWDN200530 m³/h25 m70 mmR58 029
150B42222 kWDN200330 m³/h39 m60 mmR62 557
200B42222 kWDN200550 m³/h27 m70 mmR63 988
200B43030 kWDN200–––R101 398
200B43737 kWDN200–––R120 392
200B44545 kWDN200–––R132 756

Performance for the 30 to 45 kW models is supplied with the pump; ask us for the curve.

Duckfoot assemblies and stainless steel WQK

A duckfoot bend bolts to the floor of the pump station. The pump slides down guide rails and seals onto it, so it can be lifted out for service without anyone entering the sump. Vega duckfoot assemblies suit the B and C ranges; guide rails are not included.

ItemPrice
DuckFoot 50mm Assembly – B & C Range (Excl. Guide Rails)R2 847Buy online
DuckFoot 80mm Assembly – B & C Range (Excl. Guide Rails)R5 255Buy online
DuckFoot 100mm Assembly – B & C Range (Excl. Guide Rails)R7 131Buy online
DuckFoot 150mm Assembly – B & C Range (Excl. Guide Rails)R13 589Buy online
DuckFoot 200mm Assembly – B & C Range (Excl. Guide Rails)R17 138Buy online
WQK25-18-3S Stainless Steel Submersible Sewage Pump (380V)R32 331Buy online
WQK25-18-3S Stainless Steel Submersible Sewage Pump (525V)R33 946Buy online

Sizing a sewage pump

  1. Flow. Size to the peak inflow into the sump, not the daily average. For a house, 1 to 2 l/s at peak is typical; for larger buildings add up the fixtures.
  2. Head. Vertical lift from the lowest water level in the sump to the highest point of the rising main, plus friction in the pipe and fittings.
  3. Velocity. Keep at least 0.7 m/s in the rising main so solids do not settle. Do not oversize the pipe.
  4. Solids. Grey water and drainage: screened or vortex. Raw sewage: cutter or channel impeller.
  5. Power. 220V single-phase up to 2.2 kW; larger pumps on 380V three-phase.

Worked example

A guest house needs to lift raw sewage 8 m to the municipal line through 60 m of 50 mm pipe. Peak inflow is about 12 m³/h, which gives 1.7 m/s in a 50 mm pipe, well above self-cleansing speed. Friction adds roughly 4 m, so total head is about 12 m. The 50C21.1 cutter pump (27 m³/h maximum, 15 m maximum head) suits this duty on 220V or 380V; confirm the flow at 12 m on its curve.

Installation essentials

  • Float switch or level control so the pump starts and stops with the level. The VXM has one fitted; for others add a Vega FS03 float switch or a Y1 / 30Y controller with probes.
  • Sump size so the pump runs at least a minute or two per cycle.
  • Non-return and gate valve on the discharge; use a ball-type non-return valve for raw sewage.
  • Lift on a chain or rope, never on the cable.
  • Duty and standby pumps with an alarm on critical pump stations.
  • Biological treatment. Vega Sewage & Fat Destroyer breaks down grease and fat that build up in sumps and on floats.

Price guide

RangeModelsPrice range
VX / VXM stainless steel vortex4R4 119 – R4 324Shop
WSD / WS screened cast iron 220V7R1 883 – R5 405Shop
WS screened cast iron 380V9R1 853 – R6 080Shop
C range static cutter8R7 749 – R24 379Shop
B range channel impeller9R13 669 – R132 756Shop
WQK stainless steel2R32 331 – R33 946Shop
Duckfoot assemblies5R2 847 – R17 138Shop

Prices include VAT and are correct at the time of writing. The product page always shows the current price.

Frequently asked questions

Can a Vega WSD pump handle toilet waste?

No. The WSD and WS are screened drainage and grey-water pumps for particles up to 15 to 25 mm. For raw sewage with toilet waste use the C range static cutter or the B range channel pumps.

What is a static cutter pump?

A pump with a cutting plate at the inlet that shreds solids and stringy material before the impeller, so raw sewage can go through a smaller pipe without blocking.

What is the difference between VX and VXM?

Both are stainless steel vortex pumps. The VXM is single-phase 220V with a float switch; the VX is three-phase 415V.

How big a solid can a Vega sewage pump pass?

The WSD passes 15 to 25 mm, the VX 35 mm and the B range 60 to 70 mm. The C range cuts solids rather than passing them whole.

Which Vega sewage pump for a septic tank?

For the outlet chamber with clarified water a WSD is enough. For raw sewage from the first chamber use a 50C21.1 cutter pump.

What does WSD20-15 mean?

A screened sewage and drainage pump for about 20 m³/h and up to 15 m of head, single-phase.

What is a duckfoot?

A base bend fixed to the floor of the pump station. The pump slides down guide rails and seals onto it, so it can be removed without entering the sump.

How fast should sewage move in the rising main?

At least 0.7 m/s so solids stay in suspension, and not much above 2.5 m/s to limit friction and wear.

Need a sewage pump sized?

Tell us what goes into the sump, how high and far the rising main runs, the pipe size and the power on site. We will choose the pump, float switch and fittings.

 WhatsApp us on 082 516 2248   Request a quotation