Vega Pump Controllers

A borehole pump controller sits on the surface and starts, runs and protects the submersible motor in the hole. Vega offers two levels: the MA analogue control box, which simply starts a single-phase motor, and the 20Y, Y1, 30Y and 30A intelligent controllers, which also watch the motor current and switch the pump off before it runs dry, overloads or loses a phase. This guide explains which one your pump needs and what each costs.

 

 

Motor Range

0.25 – 30 kW

220V and 380V

 

 

Dry-Run Protection

No probes needed

Current sensing on 20Y, Y1, 30Y

 

 

Analogue Boxes

From R206

Incl. VAT

 

 

Intelligent 1-Phase

R1 671

20Y, 0.37 – 2.2 kW

 

 

Intelligent 3-Phase

From R2 143

Y1, 30Y and 30A

 

 

Timers

On 0 – 48 h, off 0 – 480 min

30Y and 30A

Why the controller matters

Most borehole motors do not fail on their own. They fail because the water level dropped below the pump, the supply voltage sagged, a phase was lost or the pump was started too often. A standard control box does not see any of this. An intelligent controller measures the motor current continuously: when the current drops because the pump is sucking air, it switches off, waits, and tries again later.

Match the controller to the motor kW exactly. Single-phase controllers contain the start and run capacitors sized for one motor rating. A box from a different kW will fit the wires, but the motor will run hot and fail.

Which Vega controller do you need?

Your motorBasic start and overloadWith dry-run and voltage protection
3" 220V single-phase, 0.25 kWMA analogue control boxMA box plus a separate level switch
4" 220V single-phase, 0.37 – 2.2 kWMA analogue control box20Y intelligent controller
380V three-phase, 0.37 – 7.5 kWMotor starter to specificationY1 intelligent controller
380V three-phase, 5.5 – 15 kWMotor starter to specification30Y intelligent controller
380V three-phase, 18.5 – 30 kWMotor starter to specification30A intelligent controller
Constant pressure or soft start, any size–AR100 / AR200 VSD controller

MA analogue control boxes

The MA box is the simplest way to start a single-phase borehole motor. It houses the run capacitor and a thermal overload protector, giving protection against short circuit and over-current. Operation is manual: the pump runs when the box is switched on. IP44, ambient −25 to +55 °C.

Control boxRun capacitorPrice
C/Box STD 3" 0.25kW (220V)16 µFR206Buy online
C/Box STD 4" 0.37kW (220V)20 µFR211Buy online
C/Box STD 4" 0.55kW (220V)25 µFR224Buy online
C/Box STD 4" 0.75kW (220V)35 µFR224Buy online
C/Box STD 4" 1.1kW (220V)45 µFR246Buy online
C/Box STD 4" 1.5kW (220V)55 µFR280Buy online
C/Box STD 4" 2.2kW (220V)75 µFR364Buy online

20Y single-phase intelligent controller

For 220V single-phase deep-well pumps from 0.37 to 2.2 kW. The start capacitor is built in, so the 20Y replaces the standard control box. Non-contact current sensing detects dry running without probes in the borehole.

  • Dry-run protection with automatic restart timer
  • Overload and no-load protection
  • Over- and under-voltage protection
  • Water shortage alarm
  • Timer on/off control and LCD display
  • Size 275 × 205 × 75 mm
MotorStart capacitorPrice
0.37 kW20 µF built inR1 671Buy online
0.55 kW25 µF built inR1 671Buy online
0.75 kW35 µF built inR1 671Buy online
1.1 kW45 µF built inR1 671Buy online
1.5 kW55 µF built inR1 671Buy online
2.2 kW75 µF built inR1 671Buy online

Y1, 30Y and 30A three-phase intelligent controllers

For 380V three-phase pumps: borehole motors, centrifugal, multistage, sewage and booster pumps. All three monitor the motor current to detect dry running, and protect against overload, phase loss and voltage faults within a 304 – 456 V window.

FeatureY130Y30A
Motor power0.37 – 4 kW or 5.5 – 7.5 kW5.5 – 15 kW18.5 – 30 kW
Supply380V ±10%, 50 Hz380V ±10%, 50 Hz380V ±10%, 50 Hz
Dry-run detectionMotor currentMotor current, delay 0 – 600 sMotor current, delay 0 – 600 s
Level and pressure controlFloat switch, electrode or pressure switchFloat, electrode probe or pressure switch / contact gaugeFloat, electrode probe or pressure switch / contact gauge
TimerOn/off timerOn 0 – 48 h, off 0 – 480 minOn 0 – 48 h, off 0 – 480 min
DisplayVoltage, current, water levelVoltage, current, reservoir levelVoltage, current, reservoir level
Size320 × 220 × 125 mm310 × 254 × 106 mm300 × 400 × 190 mm
PriceR2 143R3 799R5 970

The 30Y and 30A also restart automatically after an over- or under-voltage trip once the supply returns to normal, show faults as text with an audible beep, and switch between automatic and manual mode.

Setting up dry-run protection

  1. Install and wire the controller to the motor rating on the label.
  2. Run the pump with water flowing and note the normal running current.
  3. Set the overload trip slightly above the running current and the no-load (dry-run) trip below it, as the manual describes.
  4. Set the restart delay long enough for the borehole to recover. On a low-yield hole that can be 30 minutes or more.
  5. Add a float switch or electrode probe in the tank so the pump stops when the tank is full.

Price guide

ControllerModelsPrice range
MA analogue control boxes, 220V7R206 – R364Shop
20Y intelligent, 220V single-phase6R1 671Shop
Y1 intelligent, 380V2R2 143Shop
30Y and 30A intelligent, 380V2R3 799 – R5 970Shop

Prices include VAT and are correct at the time of writing. The product page always shows the current price.

Frequently asked questions

Does a single-phase borehole pump need a control box?

Yes. The start and run capacitors for a single-phase submersible motor sit in the surface control box. Use a Vega MA box or a 20Y controller of the same kW as the motor.

What is the difference between the MA control box and the 20Y?

The MA box starts the motor and gives overload and short-circuit protection. The 20Y also detects dry running, over- and under-voltage and no-load, restarts automatically after a set delay and has a timer and LCD display.

How does the 20Y detect dry running without probes?

It measures the motor current. When the pump runs out of water the current drops, and the controller switches off, then restarts after the timer delay.

Which controller do I need for a 5.5 kW three-phase borehole pump?

The Y1 covers 5.5 to 7.5 kW in one model, and the 30Y covers 5.5 to 15 kW with a longer timer range and probe or float level control.

Can the Y1, 30Y or 30A control a sewage or booster pump?

Yes. They are general three-phase pump controllers for submersible, centrifugal, multistage, sewage and booster pumps, with float, electrode or pressure-switch control.

What voltage range do the three-phase controllers accept?

They run on 380V ±10% at 50 Hz and protect the motor outside a 304 to 456 V window.

Can I use a 20Y on a 525V pump?

No. The 20Y is for 220V single-phase motors, and the Y1, 30Y and 30A are for 380V. 525V pumps need a starter and protection built to specification.

Do I still need a pressure tank with an intelligent controller?

For a pump feeding the house directly, yes, or use a VSD controller. The Vega controllers protect the motor but do not stop rapid on-off cycling from small draws.

Not sure which controller fits?

Send us the motor kW, voltage and what the pump feeds. We will match the control box or intelligent controller and the settings.