Vega Variable Speed Drives

A Vega variable speed drive (VSD) changes the speed of a pump motor to hold a set pressure or flow, instead of switching the pump fully on and off. The result is steady pressure, soft starts that protect the motor and pipework, and lower power bills. Vega offers the F3053 frequency inverters from 0.75 to 45 kW, the AR100 intelligent pump controllers up to 110 kW and the compact AR200 for single-phase boosters. This guide explains how to choose and set one up, with current prices.

 

 

Power Range

0.75 – 110 kW

220V, 380V and 525V

 

 

Constant Pressure

4–20 mA transducer

10, 16 or 25 bar

 

 

Protection

Dry-run, overload, phase

Plus soft start and stop

 

 

F3053 VSDs

From R3 607

Incl. VAT

 

 

AR200 Controllers

From R3 064

Compact booster controller

 

 

AR100 Controllers

3 – 110 kW

380V and 525V

What a VSD does for a pump

A pump sized for the busiest moment runs flat out even when one tap is open. A VSD reads a pressure transducer on the delivery line and slows the motor down to deliver only what is being used. Because power drops sharply with speed, a pump running at 80% speed uses roughly half the power. The drive also ramps the motor up and down gently, which ends water hammer and the current surge of a direct start.

The VSD must suit the motor current, not just the kW. Check the motor nameplate current and choose a drive rated at or above it, for the right supply voltage. Submersible borehole motors need the ramp time and minimum frequency set to the motor manufacturer's limits.

Which Vega drive?

SituationVega product
House booster pump on single-phase, up to 1.5 kWAR200 1.5 kW, 230V single-phase
220V three-phase pump or motor on a single-phase supply, up to 2.2 kWF3053 220V single-phase in, three-phase out or AR200 2.2 kW
Three-phase booster or borehole pump, 380V, 0.75 – 45 kWF3053 380V VSD with a pressure transducer
525V mining or industrial supply, 0.75 – 45 kWF3053 525V VSD
Larger or dedicated constant-pressure systems, 3 – 110 kWAR100 intelligent pump controller

F3053 variable speed drives

The model code reads: F3053 series, F intelligent water pump controller, the four-digit motor power (0015 = 1.5 kW), frequency range L (0 – 400 Hz), input voltage (2 = 220V, 4 = 380V, 5 = 525V) and output phases (1 or 3). Used with a 4–20 mA pressure transducer the drive holds constant pressure and protects against motor overload, phase loss and voltage faults.

MotorCase size (H × W × D)220V in, 3-phase out380V525V
0.75 kW180 × 120 × 150 mmR3 607R3 607R3 786
1.5 kW180 × 120 × 150 mmR4 321R4 321R4 500
2.2 kW180 × 120 × 150 mmR4 761R4 761R5 199
3 kW250 × 160 × 195 mm–R5 363R5 855
4 kW250 × 160 × 195 mm–R5 910R6 457
5.5 kW250 × 160 × 195 mm–R6 566–
7.5 kW322 × 220 × 194 mm–R7 497R8 209
11 kW322 × 220 × 194 mm–R8 919R9 795
15 kW322 × 220 × 194 mm–R10 287R11 272
18.5 kW472 × 295 × 222 mm–R11 765R12 914
22 kW472 × 295 × 222 mm–R13 680R15 048
30 kW472 × 295 × 222 mm–R16 963R18 659
37 kW580 × 380 × 270 mm–R24 624R27 086
45 kW580 × 380 × 270 mm–R29 001R31 901

Case sizes are from the Vega VSD datasheet and are approximate by power band.

AR100 VSD intelligent pump controllers

The AR100 is a dedicated pump controller built on a variable speed drive. With a pressure transducer it holds constant pressure or flow, soft-starts and soft-stops the pump, and protects it against dry running, overload, phase loss and voltage faults. It suits borehole, booster, irrigation and industrial pumps.

Motor380V525V
3 kW–R5 855
4 kWR5 910R6 457
5.5 kWR6 566R7 224
7.5 kWR7 497R8 209
11 kWR8 919R9 795
15 kWR10 287R11 272
18.5 kWR11 765R12 914
22 kWR13 680R15 048
30 kWR16 963R18 659
37 kWR24 624R27 086
45 kWR29 001R31 901
55 kWR32 832R36 115
75 kWR43 776R48 154
93 kWR53 625R58 988
110 kWR65 664R72 230

AR200 compact controllers

The AR200 turns a standard pump into a constant-pressure booster with soft start, dry-run and overload protection and quiet running. Fit it with a 5-way connector, pressure gauge and a small 2 or 3 litre pressure tank from the Vega accessories range. Pump not included.

ModelMotorSupplyPrice
AR200 Intelligent Pump Controller 1.5kW (230V 1-Phase)1.5 kW230 V 1-phaseR3 064
AR200 Intelligent Pump Controller 2.2kW (230V 3-Phase)2.2 kW230 V 3-phaseR3 064
AR200 Intelligent Pump Controller 3kW (380V 3-Phase)3 kW380 V 3-phaseR4 049

Pressure transducers

RangeOutputPrice
0–10 bar4–20 mAR629Buy online
0–16 bar4–20 mAR629Buy online
0–25 bar4–20 mAR794Buy online

Choose a range comfortably above your working pressure: a 10 bar transducer for a house booster set at 3 bar, 16 or 25 bar for high-head irrigation and borehole systems.

Setting up constant pressure

  1. Mount the transducer on the delivery line after the non-return valve, with a small pressure tank close by to absorb small draws and leaks.
  2. Enter the motor data from the nameplate: rated power, voltage, current, frequency and speed.
  3. Set the target pressure, typically 2.5 – 3.5 bar for a house.
  4. Set the ramps. Short ramps for submersible motors, which must reach cooling speed quickly; longer ramps for surface pumps to prevent water hammer.
  5. Set the minimum frequency so the pump never runs below the speed at which it can lift water to the outlet.
  6. Set the sleep and dry-run functions so the pump stops when there is no demand and when it runs out of water.

Worked example

A farmhouse runs a 1.1 kW three-phase booster at 380V. With the F3053 1.1 kW drive not listed, choose the 1.5 kW 380V drive (R4 321), which covers the motor current, plus a 10 bar transducer (R629). Set 3 bar target pressure and a 2 litre tank. The pump now idles at low speed for a single tap and speeds up for a shower and garden hose together.

Installation notes

  • Ventilation. Mount the drive vertically in a clean, dry, ventilated place, out of direct sun. Heat is the main cause of drive failure.
  • Cable length. Long cables between drive and motor, typical on boreholes, may need an output filter; ask us for the limit on your model.
  • Earthing and screened cable reduce interference with other equipment.
  • Do not switch a contactor between the drive and a running motor.
  • Protect from lightning with surge protection on rural overhead supplies.

Price guide

ProductModelsPrice range
F3053 VSD, 220V single-phase in, three-phase out3R3 607 – R4 761Shop
F3053 VSD, 380V14R3 607 – R29 001Shop
F3053 VSD, 525V13R3 786 – R31 901Shop
AR100 VSD intelligent controllers29R5 855 – R72 230Shop
AR200 compact controllers3R3 064 – R4 049Shop
Pressure transducers3R629 – R794Shop

Prices include VAT and are correct at the time of writing. The product page always shows the current price.

Frequently asked questions

What is the difference between a VSD and a pump controller?

A VSD varies motor speed. The AR100 and AR200 are variable speed drives set up specifically for pumps, with constant pressure, dry-run protection and pump menus built in. The F3053 is a general VSD that also has pump control with a transducer.

Can a VSD run a three-phase pump from single-phase power?

Yes, up to 2.2 kW. The F3053 L23 models and the AR200 2.2 kW take 220V single-phase in and give 220V three-phase out, so the motor must be wound for 220V three-phase.

Does a VSD save electricity?

Yes, whenever the pump would otherwise run at full speed against a partly closed demand. Power falls roughly with the cube of speed, so a small speed reduction gives a large saving.

Which pressure transducer do I need?

A 4–20 mA transducer rated above your working pressure: 10 bar for house boosters, 16 or 25 bar for high-head systems.

Can I use a VSD on a borehole pump?

Yes. Set a short ramp and a minimum frequency that keeps the motor cooled and lifting water, and use the dry-run function. Long cables may need an output filter.

What size VSD do I need?

At least the motor kW and nameplate current, at the supply voltage on site. Where there is no exact size, go one size up.

Is the AR200 a pump?

No. It is a compact controller that mounts on your pump to make it a constant-pressure booster.

Do I still need a pressure tank?

A small one, 2 or 3 litres, so the drive can stop for very small draws and leaks without cycling.

Need a VSD specified?

Send us the motor nameplate, supply voltage, cable length and what the pump does. We will choose the drive, transducer and settings.

 WhatsApp us on 082 516 2248   Request a quotation