skip to content

Vega DZA Pumps

The Vega DZA(S) is a flanged end-suction centrifugal pump with a stainless steel 304 casing and impeller, built to the DIN 24255 standard for irrigation, water transfer and pressure boosting. It comes in four frame sizes, 50, 65, 80 and 100, either as a stub-shaft (bareshaft) pump for your own motor or complete with a 220V, 380V or 525V motor. This guide explains the model codes, performance, materials and current prices.

 

 

Power Range

1.1 – 37 kW

220V, 380V and 525V motors

 

 

Shut-off Head

Up to 57.5 m

50 to 80 series

 

 

Working Pressure

10 bar max

PN10 flanges

 

 

Liquid Temperature

−20 to +110 °C

Viton / carbon / SiC seal

 

 

Wetted Parts

304 stainless steel

316L shaft

 

 

Bareshaft Pumps

From R6 407

Incl. VAT

Why choose a stainless steel DZA?

A cast iron end-suction pump is cheaper, but it rusts in aggressive or slightly acidic water, sheds iron into clean process water and seizes after standing idle. The DZA's casing and impeller are 304 stainless steel with a 316L shaft, so it suits borehole water with a low pH, food and beverage transfer, water treatment, and liquids compatible with 304 stainless steel. It also handles water with a little grit.

It is not self-priming. Like any end-suction centrifugal pump the DZA needs a flooded suction, or a foot valve and a full suction pipe, before it starts. Keep suction lift short and never run it dry: the mechanical seal fails in minutes without water.

Reading the model code

Take DZA 65-40-160/4.0: 65 is the suction flange (DN65), 40 the discharge flange (DN40), 160 the nominal impeller diameter in mm, and 4.0 the motor power in kW. A larger impeller gives more head; a larger flange size gives more flow.

Stub-shaft or complete with motor?

OptionWhat you getChoose it when
Stub-shaft (bareshaft)Pump only, for coupling to your own motor on a base plateYou have a motor, need a special voltage, or are replacing a worn pump end
Complete with motorPump and motor as one unit, 220V (to 2.2 kW), 380V or 525VA new installation that should be ready to connect

Models, performance and prices

ModelShut-off headBareshaftWith 220V motorWith 380V motorWith 525V motor
DZA 50-32-125 / 1.1 kW–R6 407R9 215R9 889R9 889
DZA 50-32-160 / 1.5 kW29.5 mR7 301R10 581R10 864R10 864
DZA 50-32-160 / 2.2 kW37 mR7 313R11 849R12 468R12 468
DZA 50-32-200 / 3 kW45 mR9 099–R14 918R14 918
DZA 50-32-200 / 4 kW55 mR9 324–R16 439R16 439
DZA 50-32-200 / 5.5 kW–R9 351–R20 364R20 364
DZA 65-40-125 / 1.5 kW20 mR6 808R10 243R10 526R10 526
DZA 65-40-125 / 2.2 kW26 mR8 054R12 352R12 958R12 958
DZA 65-40-160 / 3 kW31 mR8 092–R14 621R14 214
DZA 65-40-160 / 4 kW39 mR8 079–R15 546R15 546
DZA 65-40-200 / 5.5 kW47 mR10 394–R20 957R20 957
DZA 65-40-200 / 7.5 kW57 mR10 491–R21 961R22 527
DZA 65-50-125 / 3 kW22.5 mR8 684–R14 621R14 621
DZA 65-50-125 / 4 kW25.5 mR8 529–R15 855R15 855
DZA 65-50-160 / 5.5 kW33 mR9 669–R20 458R20 458
DZA 65-50-160 / 7.5 kW39 mR9 701–R21 984R21 984
DZA 65-50-190 / 11 kW–R11 362–R33 033R33 033
DZA 65-50-200 / 11 kW57.5 mR11 519–R33 140R33 140
DZA 80-65-125 / 4 kW–R10 279–R17 058R17 058
DZA 80-65-125 / 5.5 kW22.5 mR11 127–R21 461R21 461
DZA 80-65-125 / 7.5 kW27.5 mR11 118–R22 957R22 957
DZA 80-65-156 / 11 kW–R13 576–R34 554R34 554
DZA 80-65-160 / 11 kW36 mR14 407–R35 124R35 124
DZA 80-65-200 / 15 kW44 mR15 767–R42 101R42 101
DZA 80-65-200 / 18.5 kW51 mR16 016–R46 544R46 544
DZA 80-65-200 / 22 kW57 mR16 226–R66 178R66 178
DZA 100-80-160 / 11 kW–R13 178–R34 585R34 585
DZA 100-80-160 / 15 kW–R13 226–R34 617R34 617
DZA 100-80-160 / 18.5 kW–R13 379–R40 789R40 789
DZA 100-80-160 / 22 kW–R12 876–R54 014R54 014
DZA 100-80-200 / 30 kW–R17 557–R67 424R67 424
DZA 100-80-200 / 37 kW–R17 941–R77 796R77 796

Shut-off head is the head at zero flow from the Vega performance table. Select at your working flow from the curve on the product page. – means not listed or not published.

Sizing a DZA pump

  1. Flow. Work out the flow you need in m³/h: irrigation area × application rate, or the transfer volume divided by the time available.
  2. Total head. Static height from water level to outlet + friction in the pipes and fittings + the pressure needed at the outlet (10 m per bar).
  3. Series. Larger flows need a larger frame: the 50 series for smaller duties, 65 and 80 for irrigation and transfer, 100 for high-volume work.
  4. Model. Choose the model whose curve passes through your flow at your head, close to the middle of the curve where efficiency is best.
  5. Motor. Match the supply: 220V single-phase up to 2.2 kW, otherwise 380V or 525V three-phase.

Worked example

A packhouse must transfer water at 20 m³/h to a tank 18 m above the pump, with about 7 m of pipe friction: total head 25 m. The 65-40-125/2.2 has a shut-off head of 26 m, too close to the duty. The 65-40-160/3.0 (31 m shut-off) or 65-40-160/4.0 (39 m) sit comfortably above it; check the curve at 20 m³/h and pick the smaller one that meets 25 m.

Construction and operating limits

ItemSpecification
StandardDIN 24255 end-suction, flanged
CasingAISI 304 stainless steel
ImpellerAISI 304 stainless steel
ShaftAISI 316L stainless steel
Mechanical sealViton / carbon / silicon carbide
Maximum working pressure10 bar
Liquid temperature−20 °C to +110 °C
LiquidsWater, water with light grit, liquids compatible with 304 stainless steel

Installation notes

  • Bolt the pump and motor to a rigid base and align the coupling on stub-shaft installations; misalignment destroys bearings and seals.
  • Suction pipe one size larger than the pump inlet, short, airtight, with an eccentric reducer flat side up so no air collects.
  • Fit valves on both sides so the pump can be removed without draining the system, and a non-return valve on the discharge.
  • Support the pipework independently; the pump flanges must not carry pipe weight.
  • Protect the motor with a correctly set overload, or use a Vega 30Y / 30A controller or VSD for dry-run and soft-start protection.

Price guide

SeriesModelsPrice range
DZA 50 bareshaft6R6 407 – R9 351Shop
DZA 50 with motor15R9 215 – R20 364Shop
DZA 65 bareshaft12R6 808 – R11 519Shop
DZA 65 with motor26R10 243 – R33 140Shop
DZA 80 bareshaft8R10 279 – R16 226Shop
DZA 80 with motor16R17 058 – R66 178Shop
DZA 100 bareshaft6R12 876 – R17 941Shop
DZA 100 with motor12R34 585 – R77 796Shop

Prices include VAT and are correct at the time of writing. The product page always shows the current price.

Frequently asked questions

What does DZA(S) 65-40-160/4.0 mean?

DN65 suction, DN40 discharge, a 160 mm nominal impeller and a 4.0 kW motor.

What is a stub-shaft or bareshaft pump?

The pump end without a motor, with a shaft extension for coupling to a separate motor on a base plate.

Is the Vega DZA self-priming?

No. It needs a flooded suction, or a foot valve and a primed suction pipe, before starting.

What temperature can the DZA handle?

Liquids from −20 °C to +110 °C, with a Viton, carbon and silicon carbide mechanical seal.

What pressure is the DZA rated for?

A maximum working pressure of 10 bar.

Why stainless steel instead of cast iron?

Stainless steel does not rust or discolour the water, resists low-pH borehole water and suits food, beverage and treatment duties.

Which motor voltage should I choose?

220V single-phase is offered up to 2.2 kW. Larger pumps and most farm and industrial sites use 380V or 525V three-phase.

How do I choose between the 50, 65, 80 and 100 series?

By flow. The flange size limits flow; pick the smallest series whose curve covers your flow at your head, then the model by impeller size and kW.

Need a DZA pump sized?

Send us the flow, the height and distance to the outlet, the liquid and the power on site. We will select the model and motor.

 WhatsApp us on 082 516 2248   Request a quotation