Vega DZA Pumps
The Vega DZA(S) is a flanged end-suction centrifugal pump with a stainless steel 304 casing and impeller, built to the DIN 24255 standard for irrigation, water transfer and pressure boosting. It comes in four frame sizes, 50, 65, 80 and 100, either as a stub-shaft (bareshaft) pump for your own motor or complete with a 220V, 380V or 525V motor. This guide explains the model codes, performance, materials and current prices.
Power Range
1.1 – 37 kW
220V, 380V and 525V motors
Shut-off Head
Up to 57.5 m
50 to 80 series
Working Pressure
10 bar max
PN10 flanges
Liquid Temperature
−20 to +110 °C
Viton / carbon / SiC seal
Wetted Parts
304 stainless steel
316L shaft
Bareshaft Pumps
From R6 407
Incl. VAT
Why choose a stainless steel DZA?
A cast iron end-suction pump is cheaper, but it rusts in aggressive or slightly acidic water, sheds iron into clean process water and seizes after standing idle. The DZA's casing and impeller are 304 stainless steel with a 316L shaft, so it suits borehole water with a low pH, food and beverage transfer, water treatment, and liquids compatible with 304 stainless steel. It also handles water with a little grit.
It is not self-priming. Like any end-suction centrifugal pump the DZA needs a flooded suction, or a foot valve and a full suction pipe, before it starts. Keep suction lift short and never run it dry: the mechanical seal fails in minutes without water.
Reading the model code
Take DZA 65-40-160/4.0: 65 is the suction flange (DN65), 40 the discharge flange (DN40), 160 the nominal impeller diameter in mm, and 4.0 the motor power in kW. A larger impeller gives more head; a larger flange size gives more flow.
Stub-shaft or complete with motor?
| Option | What you get | Choose it when |
|---|---|---|
| Stub-shaft (bareshaft) | Pump only, for coupling to your own motor on a base plate | You have a motor, need a special voltage, or are replacing a worn pump end |
| Complete with motor | Pump and motor as one unit, 220V (to 2.2 kW), 380V or 525V | A new installation that should be ready to connect |
Models, performance and prices
| Model | Shut-off head | Bareshaft | With 220V motor | With 380V motor | With 525V motor |
|---|---|---|---|---|---|
| DZA 50-32-125 / 1.1 kW | – | R6 407 | R9 215 | R9 889 | R9 889 |
| DZA 50-32-160 / 1.5 kW | 29.5 m | R7 301 | R10 581 | R10 864 | R10 864 |
| DZA 50-32-160 / 2.2 kW | 37 m | R7 313 | R11 849 | R12 468 | R12 468 |
| DZA 50-32-200 / 3 kW | 45 m | R9 099 | – | R14 918 | R14 918 |
| DZA 50-32-200 / 4 kW | 55 m | R9 324 | – | R16 439 | R16 439 |
| DZA 50-32-200 / 5.5 kW | – | R9 351 | – | R20 364 | R20 364 |
| DZA 65-40-125 / 1.5 kW | 20 m | R6 808 | R10 243 | R10 526 | R10 526 |
| DZA 65-40-125 / 2.2 kW | 26 m | R8 054 | R12 352 | R12 958 | R12 958 |
| DZA 65-40-160 / 3 kW | 31 m | R8 092 | – | R14 621 | R14 214 |
| DZA 65-40-160 / 4 kW | 39 m | R8 079 | – | R15 546 | R15 546 |
| DZA 65-40-200 / 5.5 kW | 47 m | R10 394 | – | R20 957 | R20 957 |
| DZA 65-40-200 / 7.5 kW | 57 m | R10 491 | – | R21 961 | R22 527 |
| DZA 65-50-125 / 3 kW | 22.5 m | R8 684 | – | R14 621 | R14 621 |
| DZA 65-50-125 / 4 kW | 25.5 m | R8 529 | – | R15 855 | R15 855 |
| DZA 65-50-160 / 5.5 kW | 33 m | R9 669 | – | R20 458 | R20 458 |
| DZA 65-50-160 / 7.5 kW | 39 m | R9 701 | – | R21 984 | R21 984 |
| DZA 65-50-190 / 11 kW | – | R11 362 | – | R33 033 | R33 033 |
| DZA 65-50-200 / 11 kW | 57.5 m | R11 519 | – | R33 140 | R33 140 |
| DZA 80-65-125 / 4 kW | – | R10 279 | – | R17 058 | R17 058 |
| DZA 80-65-125 / 5.5 kW | 22.5 m | R11 127 | – | R21 461 | R21 461 |
| DZA 80-65-125 / 7.5 kW | 27.5 m | R11 118 | – | R22 957 | R22 957 |
| DZA 80-65-156 / 11 kW | – | R13 576 | – | R34 554 | R34 554 |
| DZA 80-65-160 / 11 kW | 36 m | R14 407 | – | R35 124 | R35 124 |
| DZA 80-65-200 / 15 kW | 44 m | R15 767 | – | R42 101 | R42 101 |
| DZA 80-65-200 / 18.5 kW | 51 m | R16 016 | – | R46 544 | R46 544 |
| DZA 80-65-200 / 22 kW | 57 m | R16 226 | – | R66 178 | R66 178 |
| DZA 100-80-160 / 11 kW | – | R13 178 | – | R34 585 | R34 585 |
| DZA 100-80-160 / 15 kW | – | R13 226 | – | R34 617 | R34 617 |
| DZA 100-80-160 / 18.5 kW | – | R13 379 | – | R40 789 | R40 789 |
| DZA 100-80-160 / 22 kW | – | R12 876 | – | R54 014 | R54 014 |
| DZA 100-80-200 / 30 kW | – | R17 557 | – | R67 424 | R67 424 |
| DZA 100-80-200 / 37 kW | – | R17 941 | – | R77 796 | R77 796 |
Shut-off head is the head at zero flow from the Vega performance table. Select at your working flow from the curve on the product page. – means not listed or not published.
Sizing a DZA pump
- Flow. Work out the flow you need in m³/h: irrigation area × application rate, or the transfer volume divided by the time available.
- Total head. Static height from water level to outlet + friction in the pipes and fittings + the pressure needed at the outlet (10 m per bar).
- Series. Larger flows need a larger frame: the 50 series for smaller duties, 65 and 80 for irrigation and transfer, 100 for high-volume work.
- Model. Choose the model whose curve passes through your flow at your head, close to the middle of the curve where efficiency is best.
- Motor. Match the supply: 220V single-phase up to 2.2 kW, otherwise 380V or 525V three-phase.
Worked example
A packhouse must transfer water at 20 m³/h to a tank 18 m above the pump, with about 7 m of pipe friction: total head 25 m. The 65-40-125/2.2 has a shut-off head of 26 m, too close to the duty. The 65-40-160/3.0 (31 m shut-off) or 65-40-160/4.0 (39 m) sit comfortably above it; check the curve at 20 m³/h and pick the smaller one that meets 25 m.
Construction and operating limits
| Item | Specification |
|---|---|
| Standard | DIN 24255 end-suction, flanged |
| Casing | AISI 304 stainless steel |
| Impeller | AISI 304 stainless steel |
| Shaft | AISI 316L stainless steel |
| Mechanical seal | Viton / carbon / silicon carbide |
| Maximum working pressure | 10 bar |
| Liquid temperature | −20 °C to +110 °C |
| Liquids | Water, water with light grit, liquids compatible with 304 stainless steel |
Installation notes
- Bolt the pump and motor to a rigid base and align the coupling on stub-shaft installations; misalignment destroys bearings and seals.
- Suction pipe one size larger than the pump inlet, short, airtight, with an eccentric reducer flat side up so no air collects.
- Fit valves on both sides so the pump can be removed without draining the system, and a non-return valve on the discharge.
- Support the pipework independently; the pump flanges must not carry pipe weight.
- Protect the motor with a correctly set overload, or use a Vega 30Y / 30A controller or VSD for dry-run and soft-start protection.
Price guide
| Series | Models | Price range | |
|---|---|---|---|
| DZA 50 bareshaft | 6 | R6 407 – R9 351 | Shop |
| DZA 50 with motor | 15 | R9 215 – R20 364 | Shop |
| DZA 65 bareshaft | 12 | R6 808 – R11 519 | Shop |
| DZA 65 with motor | 26 | R10 243 – R33 140 | Shop |
| DZA 80 bareshaft | 8 | R10 279 – R16 226 | Shop |
| DZA 80 with motor | 16 | R17 058 – R66 178 | Shop |
| DZA 100 bareshaft | 6 | R12 876 – R17 941 | Shop |
| DZA 100 with motor | 12 | R34 585 – R77 796 | Shop |
Prices include VAT and are correct at the time of writing. The product page always shows the current price.
Frequently asked questions
What does DZA(S) 65-40-160/4.0 mean?
DN65 suction, DN40 discharge, a 160 mm nominal impeller and a 4.0 kW motor.
What is a stub-shaft or bareshaft pump?
The pump end without a motor, with a shaft extension for coupling to a separate motor on a base plate.
Is the Vega DZA self-priming?
No. It needs a flooded suction, or a foot valve and a primed suction pipe, before starting.
What temperature can the DZA handle?
Liquids from −20 °C to +110 °C, with a Viton, carbon and silicon carbide mechanical seal.
What pressure is the DZA rated for?
A maximum working pressure of 10 bar.
Why stainless steel instead of cast iron?
Stainless steel does not rust or discolour the water, resists low-pH borehole water and suits food, beverage and treatment duties.
Which motor voltage should I choose?
220V single-phase is offered up to 2.2 kW. Larger pumps and most farm and industrial sites use 380V or 525V three-phase.
How do I choose between the 50, 65, 80 and 100 series?
By flow. The flange size limits flow; pick the smallest series whose curve covers your flow at your head, then the model by impeller size and kW.
Need a DZA pump sized?
Send us the flow, the height and distance to the outlet, the liquid and the power on site. We will select the model and motor.
Related guides
- Vega Surface Pumps
- Vega DL Pumps — vertical multistage
- Vega Variable Speed Drives
- Vega Pumps