skip to content

Wilo 4 Inch Borehole Pumps

Wilo 4” submersible borehole pumps are multistage centrifugal pumps that fit a standard 100 mm (4”) borehole and lift water from depths of 20 m to over 250 m. The pump end (hydraulic) is bought separately from the 4” motor and its control box, so the same pump can be matched to the motor size the duty needs. We currently have Wilo Actun FIRST and XIRO SPU4 pump ends, 0.37 kW and 0.55 kW oil-filled 230 V motors with matching control boxes, and ready-matched complete sets on clearance at reduced prices. Prices include VAT; stock is limited to the quantities on hand.

Nominal flow range

1 to 8 m³/h

Series 01, 02, 03, 04, 05, 06, 08 and 09

Maximum head

up to 253 m

XIRO SPU4-01-38 (38 stages)

Motor sizes

0.37 to 4.0 kW

0.37 and 0.55 kW 230 V motors in stock

Power supply

230 V single phase

Sets ship with the matching control box

Borehole size

4” (100 mm) minimum

Pump diameter 98 mm, NEMA 4” motor coupling

Outlet connection

Rp 1¼ to Rp 2

Series 01–04: Rp 1¼, 05: Rp 1½, 06/08: Rp 2

What is on special

How to choose the right pump

Step 1 – flow. Pick the series by the flow you need at the tap, tank or irrigation line. The series number is the nominal flow in m³/h: series 01 = 1 m³/h (about 17 l/min), 02 = 2 m³/h, 03 = 3 m³/h and so on. A household with a 5 000 l tank is usually a series 01 to 03 pump; small irrigation and livestock a series 05 to 09 pump.

Step 2 – head. Add up the total head: the pumping water level in the borehole (not the borehole depth) + the height to the tank or highest tap + friction loss in the pipe (roughly 5 m per 100 m of correctly sized pipe) + any pressure you want at the outlet (10 m per bar). Choose the model whose head at your flow, in the performance tables below, is a little more than that number. The second number in the model code is the number of stages – more stages, more head.

Step 3 – motor. Each pump end lists the motor it is designed for. Pump ends for 0.37 kW and 0.55 kW motors can be bought as a complete set with the 230 V oil-filled motor and control box. Larger pump ends (0.75 to 4 kW) are supplied as hydraulics only – send us the model and we will quote the matching motor.

SeriesNominal flowTypical flow rangeTypical use
011 m³/h0.3 – 1.5 m³/hDeep, low-yield boreholes; household tank filling
022 m³/h0.9 – 3 m³/hHousehold supply, small garden
033 m³/h1.2 – 4.2 m³/hHousehold plus garden irrigation
044 m³/h2 – 5 m³/hSmallholding, livestock water
055 m³/h2.5 – 7 m³/hIrrigation, multiple houses
066 m³/h2.1 – 6 m³/hIrrigation, farm supply
08 / 098 – 9 m³/h4.8 – 12 m³/hLarger irrigation blocks, bulk tank filling

Wilo Actun FIRST SPU4 pump ends – specifications and prices

Hydraulic pump end only (no motor). Max head is the closed-valve head from the Wilo data sheet for the complete 230 V unit; models marked * are estimated from the stage count and should be confirmed with us before ordering. Hydraulic length is the pump end without motor.

ModelWilo no.StagesMax headOutletHydraulic lengthFor motorIn stockPrice incl. VAT
SPU4-01-10-B6083511A1066 mRp 1¼327 mm0.37 kW33R 704.14Buy online
SPU4-01-13-B6083512A1386 mRp 1¼381 mm0.37 kW244R 875.85Buy online
SPU4-02-07-B6083517A748 mRp 1¼268 mm0.37 kW12R 600.76Buy online
SPU4-02-10-B6083518A1068 mRp 1¼321 mm0.55 kW18R 1 045.09Buy online
SPU4-02-14-B6083519A1495 mRp 1¼390 mm0.75 kW2R 1 348.79Buy online
SPU4-02-28-B6089367A28190 m *Rp 1¼–1.5 kW26R 1 982.90Buy online
SPU4-03-05-B6083521A533 mRp 1¼231 mm0.37 kW3R 591.96Buy online
SPU4-03-08-B6083522A853 mRp 1¼283 mm0.55 kW2R 671.49Buy online
SPU4-03-40-B6083527A40265 m *Rp 1¼–2.2 kW2R 1 705.98Buy online
SPU4-04-07-B6083528A745 mRp 1¼301 mm0.55 kW4R 591.61Buy online
SPU4-04-18-B6083531A18115 mRp 1¼538 mm1.5 kW1R 970.68Buy online
SPU4-05-04-B6083535A426 mRp 1½249 mm0.37 kW3R 826.10Buy online
SPU4-05-06-B6083536A638 mRp 1½299 mm0.55 kW2R 957.54Buy online
SPU4-05-08-B6083537A851 mRp 1½348 mm0.75 kW3R 1 046.41Buy online
SPU4-05-12-B6083538A1277 mRp 1½437 mm1.1 kW2R 1 347.87Buy online
SPU4-05-44-B6083542A44281 m *Rp 1½–4.0 kW1R 3 386.73Buy online
SPU4-06-10-B6083544A1061 mRp 2488 mm1.1 kW2R 1 449.47Buy online
SPU4-08-08-B6083552A851 mRp 2422 mm1.5 kW2R 1 313.27Buy online

Wilo XIRO SPU4 pump ends – specifications and prices

B2 hydraulic pump ends only (no motor). Head values are from the Wilo XIRO selection charts.

ModelWilo no.StagesMax headOutletWeightFor motorIn stockPrice incl. VAT
SPU4-01-10-B22759001A1067 mRp 1¼3.3 kg0.37 kW365R 973.66Buy online
SPU4-01-13-B22759002A1386 mRp 1¼3.7 kg0.37 kW201R 1 246.26Buy online
SPU4-01-38-B22759005A38253 mRp 1¼9.2 kg1.1 kW13R 2 817.05Buy online
SPU4-02-07-B22759014A746 mRp 1¼2.8 kg0.37 kW18R 936.74Buy online
SPU4-03-05-B22759021A534 mRp 1¼2.5 kg0.37 kW10R 743.57Buy online
SPU4-03-08-B22759022A854 mRp 1¼2.9 kg0.55 kW6R 953.73Buy online
SPU4-06-04-B22759041A426 mRp 1½2.4 kg0.37 kW8R 685.32Buy online
SPU4-09-08-B22759063A852 mRp 1½4.0 kg1.5 kW6R 1 171.24Buy online

XIRO performance – head (m) at flow (m³/h)

Model00.30.60.91.21.5
SPU4-01-10676355463318
SPU4-01-13867870564223
SPU4-01-3825323420816911752
Model00.91.21.51.82.12.42.73
SPU4-02-07464342393633292622
SPU4-02-10676461585449433628
SPU4-02-14928683797467605242
Model01.21.82.433.64.2
SPU4-03-0534323027231811
SPU4-03-0854514943383019
Model02.12.433.64.24.85.46
SPU4-06-0426232221191714117
Model04.85.467.28.49.610.812
SPU4-09-08524745444137312518

4” motors and control boxes

Wilo X4-OR oil-filled 4” submersible motors, NEMA coupling, 230 V 50 Hz single phase, with 1.5 m motor lead. The control box holds the start/run capacitor and overload protection and must match the motor size.

ItemWilo no.RatingSupplyDetailsIn stockPrice incl. VAT
X4-OR-0.37-1-230-50-B227596010.37 kW230 V 1~3.3 A, length 361 mm313R 1 506.50Buy online
X4-OR-0.55-1-230-50-B227596020.55 kW230 V 1~4.4 A, length 381 mm25R 1 657.43Buy online
CB-0.37-230-50-RC16-PG27597000.37 kW230 V 1~Capacitor + overload, wall mount346R 326.31Buy online
CB-0.55-230-50-RC20-PG27597010.55 kW230 V 1~Capacitor + overload, wall mount97R 340.68Buy online

Complete 4” borehole pump sets

Each set is the pump end, the matching X4-OR oil-filled 230 V motor and the control box, assembled and ready to install. The sets below are the only pump ends in this clearance that can be matched to the 0.37 kW and 0.55 kW motors in stock.

SetPump endMax headNominal flowMotorSupplyIn stockPrice incl. VAT
Wilo Actun FIRST SPU4-01-10 set – 0.37 kW 230 V01-10 (FIRST)66 m1 m³/h0.37 kW230 V 1~33R 2 536.95Buy online
Wilo Actun FIRST SPU4-01-13 set – 0.37 kW 230 V01-13 (FIRST)86 m1 m³/h0.37 kW230 V 1~244R 2 708.66Buy online
Wilo Actun FIRST SPU4-02-07 set – 0.37 kW 230 V02-07 (FIRST)48 m2 m³/h0.37 kW230 V 1~12R 2 433.57Buy online
Wilo Actun FIRST SPU4-02-10 set – 0.55 kW 230 V02-10 (FIRST)68 m2 m³/h0.55 kW230 V 1~18R 3 043.21Buy online
Wilo Actun FIRST SPU4-03-05 set – 0.37 kW 230 V03-05 (FIRST)33 m3 m³/h0.37 kW230 V 1~3R 2 424.77Buy online
Wilo Actun FIRST SPU4-03-08 set – 0.55 kW 230 V03-08 (FIRST)53 m3 m³/h0.55 kW230 V 1~2R 2 669.62Buy online
Wilo Actun FIRST SPU4-04-07 set – 0.55 kW 230 V04-07 (FIRST)45 m4 m³/h0.55 kW230 V 1~4R 2 589.74Buy online
Wilo Actun FIRST SPU4-05-04 set – 0.37 kW 230 V05-04 (FIRST)26 m5 m³/h0.37 kW230 V 1~3R 2 658.91Buy online
Wilo Actun FIRST SPU4-05-06 set – 0.55 kW 230 V05-06 (FIRST)38 m5 m³/h0.55 kW230 V 1~2R 2 955.67Buy online
Wilo SPU4-01-10 set – 0.37 kW 230 V01-10 (XIRO)67 m1 m³/h0.37 kW230 V 1~313R 2 806.47Buy online
Wilo SPU4-01-13 set – 0.37 kW 230 V01-13 (XIRO)86 m1 m³/h0.37 kW230 V 1~201R 3 079.08Buy online
Wilo SPU4-02-07 set – 0.37 kW 230 V02-07 (XIRO)46 m2 m³/h0.37 kW230 V 1~18R 2 769.55Buy online
Wilo SPU4-03-05 set – 0.37 kW 230 V03-05 (XIRO)34 m3 m³/h0.37 kW230 V 1~10R 2 576.38Buy online
Wilo SPU4-03-08 set – 0.55 kW 230 V03-08 (XIRO)54 m3 m³/h0.55 kW230 V 1~6R 2 951.86Buy online
Wilo SPU4-06-04 set – 0.37 kW 230 V06-04 (XIRO)26 m6 m³/h0.37 kW230 V 1~8R 2 518.14Buy online

Installation guidelines

  • Install the pump at least 1 m above the bottom of the borehole and fully below the pumping water level; the motor must stay submerged with water flowing past it (minimum 0.08 m/s past a 4” motor – use a cooling shroud in wide boreholes or sumps).
  • Hang the pump on the rising main, never on the cable. Fit a safety rope through the pump’s rope eyes and tie it off at the well head.
  • Use a non-return valve within 10 m of the pump if the pump end does not have one built in, and another at the surface on long pipelines.
  • Use submersible cable sized for the motor current and the full length to the control box – see our cable sizing guide. Join the motor lead with a heat-shrink or resin joint kit.
  • Protect the motor with the matching control box and a dry-run protector or level probes; a borehole pump that runs dry is destroyed in minutes.
  • Check rotation (three-phase only) and never throttle the pump to below the minimum flow of its series.

Frequently asked questions

What is the difference between a pump end and a complete pump?

The pump end (hydraulic) is the stack of impellers and the outlet with a NEMA 4” coupling. It does nothing without a motor. A complete pump or set adds the submersible motor and, for single phase, the control box with the capacitor.

Can I fit the pump end to a motor I already have?

Yes, if the motor is a standard NEMA 4” motor of the power listed for that pump end (or one size bigger). Send us the motor nameplate and we will confirm.

What is the difference between Actun FIRST and XIRO?

Both are Wilo 4” multistage borehole pumps with the same NEMA coupling. Actun FIRST is the current stainless-steel/Noryl range; XIRO SPU4 B2 is the earlier design. Hydraulically they cover the same duties and both carry the Wilo warranty.

Will a 0.37 kW pump fill my tank?

A series 01 to 03 pump with 0.37 kW gives 1 to 3 m³/h (17 to 50 l/min) at 30 to 60 m head – enough for most household tanks. Use the performance tables to match your water level and tank height.

Does the price include the motor?

Pump ends and motors are priced separately; the complete sets include the pump end, motor and control box. All prices include VAT.

Is stock limited?

Yes. These are clearance quantities – the in-stock column shows what is available, and once a model is sold out it will not be restocked at this price.

Pricing summary

RangeModelsPrice incl. VAT
Actun FIRST pump ends18R 591.61 – R 3 386.73
XIRO SPU4 pump ends8R 685.32 – R 2 817.05
Complete sets15R 2 424.77 – R 3 079.08
4” motors2R 1 506.50 – R 1 657.43
Control boxes2R 326.31 – R 340.68
Accessories2R 28.75 – R 230.00

Pump ends for 0.75 kW and larger motors are supplied as hydraulics only – ask us for a motor and control box or starter to match. Delivery nationwide.

Get help choosing the right borehole pump

Send us your borehole water level, the height to the tank and the flow you need, and we will match a pump, motor and cable for you.

WhatsApp us on 082 516 2248 Request a quotation